preload-image

drawing detail underground ductile iron pipe

buried Ductile Iron Pipe is provided in ANSI/AWWA Standard C150/ A21.50.1 This procedure is based on the teachings of Merlin Spangler and others, and utilizes the same procedures used in the venerable design standard ANSI A21.12 for Cast Iron pipe. The design method is based on two assumptions: 1.

Aug 14, 2019· 2. install 18" length of 3/ 4" pvc pipe to ensure that the terminal box will remain in the install 18" length of 3/ 4" pvc pipe to ensure that the terminal box will remain in the u൐right position. position the pipe so that the terminal box will be as high as possible with the cast iron lid still closing properly. finished grade ...

Standard Sewer Detail Drawings S-1 Standard Bedding for RCP ... S-31 Lateral Saddle Installation Detail for PVC Pipe ... REQUIREMENTS FOR DUCTILE IRON NOTES: 1. TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BE TAKEN FROM THE INSIDE FACE OF THE SHORING AND BRACING. 2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL …

Ductile iron C110/A21.10 flanged fittings are rated for 150 or 250 psi water working pressure as listed in the tables. Long radius and reducing elbows, reducing on-the-run tees, side outlet fittings, eccentric reducers and laterals are ANSI B16.1 Class 125 fittings. Ductile iron Class 125 …

b. Ductile iron pipe, fittings, valves, and accessories shall be loaded and unloaded by lifting with hoists or skidding so as to avoid shock or damage. Under no circumstances shall such materials be dropped. Pipe handled, on skidways shall not be skidded or rolled against pipe already on the ground. 2.

Sep 02, 2008· Surface Primer for Underground Application of Petrolatum Wax Tape. PIPE, COPPER TUBING 1" and 2" type K Soft Seamless Tubing PIPE, DUCTILE IRON For Water Lines 4" and Larger Manufactured per AWWA C111, C115, C150, C151. Double Cement Mortar Lined. MORTAR, REPAIR Single or Two Component, Low Shrinkage, Cement Based

Mar 21, 2012· one length mechanical joint ductile iron pipe (min 12') one length mechanical joint ductile iron pipe (min 12') one length mechanical joint ductile iron pipe ductile iron pipe standard utility crossing water & wastewater services engineering division 2555 west copans road pompano beach, fl 33069 phone no. 954-831-0745 fax: 954-831-0925 standard ...

4. AWWA C111 - Standard for Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings. 5. AWWA C115 - Standard for Flanged Ductile-Iron Pipe with Ductile-Iron or Gray-Iron Threaded Flanges. 6. AWWA C151 - Standard for Ductile-Iron Pipe, Centrifugally Cast, …

Ductile Iron pipe and fittings are most often joined with push-on (Figure 1) or mechanical joints. Neither of these joints provides significant restraint against longitudinal separation other than the friction between the gasket and the plain end of the pipe or fitting.

2.05 PIPE COATING AND LINING A. All ductile iron pipe and fittings and cast iron fittings buried underground or submerged shall have a standard bituminous outside coating conforming to ANSI A21.6 or A21.51. All exposed ductile iron pipe and ductile iron and cast iron fittings shall have an outside coating of universal primer. B.

W6.10A- Steel Pipe Buttstrap (DWG) W6.11- 4 Inch to 16 Inch In-Line Thrust Block for Ductile Iron Pipe (DWG) W6.12A- Wrought Iron Fence and Gate Detail (DWG) W6.12B- Wrought Iron Drive Swing Gate Detail (DWG) W6.12C- Wrought Iron Drive Swing Gate Operator Detail (DWG) W6.12D- Chain Link Fence Detail (DWG) W6.12E- Chain Link Gate Detail (DWG)

Pipe Chair Page 37 Figure 158 Ductile Iron Pipe Clamp Page 38 Figure 158DB Double Bolt Ductile Iron Pipe Clamp Page 38 Figures 175, 175SP Two Bolt Pipe Clamp Page 40 Figure 179 Offset Pipe Clamp Page 39 Figure 200 Light Duty Clevis Hanger Page 41 Figure 200V Vee Clevis Hanger Page 42 Figure 200VT Vee Trough Page 86 Figure 221 Wall Pipe Support ...

Sep 25, 2002· Section 8 Ductile Iron Pipe and Fittings 1. Scope 2. Pipe 3. Fittings Section 9 PVC Pipe 2" and 6" Only 1. Scope 2. Pipe 3. Fittings 4. Special Instructions Section 10 Miscellaneous 1. Scope 2. Water Services Section 11 Standard Specification for Materials Section 12 Standard Detail Drawings Section 13 Backflow Prevention

35 Air Release and Blow-Off Piping – Ductile Iron Pipe 12" & Larger 36 2" Blow-Off 37 Automatic Flushing Device and Drainage Piping 38 8" & 12" Headwall Blow-Off 39 4" Through 12" Pressure Reducing Valve Vault 39A 4" Through 12" Pressure Reducing Valve Vault – Vault Notes 40 Vault Access Door Installation and Drain Pipe

A. Mechanical joint restraints for Ductile Iron pipe and PVC pipe sizes 4-inches thru 24-inches shall be Mega-Lug® type as manufactured by EBAA, Inc. Series 1100 or Uni Flange Retainer (UFR 1400 D) for Ductile Iron pipe and EBAA, Inc. Series 2000PV or Ford …

Ductile Iron pipe is defined as rigid conduit. Mechanical or push-on joints shall conform to AWWA Standard C-110. 2-5 SEWER PIPE AND APPURTENANCES – PRESSURE Unless otherwise specified, pressure pipe shall be constructed of: (a) High Density Polyethylene (HDPE) pipe conforming to ASTM 3035 with the type of

A. All ductile iron pipe and fittings and cast iron fittings buried underground or submerged shall have a standard bituminous outside coating conforming to ANSI A2 1.6 or A21.51. All exposed ductile iron pipe and ductile iron and cast iron fittings shall have an outside coating of universal primer. B.

1.06.19 Contractor Approves Drawings And Specifications As Involving I-12 ... 1.07.7 Underground Facilities I-19 ... 5.02 Laying Ductile Iron Pipe And Fittings V-5 5.03 Furnishing And Delivering Ductile Iron Fittings V-17 5.04 Furnishing, Delivering And Laying Steel Pipe And Appurtenances V-20 ...

2 hole pipe strap a 50 231 45 163 malleable iron slit ring hanger a 129 138 r 38 r 129 heavy duty short strap a 58 262 46 162 offset pipe clamp a 500 103 one hole pipe clamp a 132 126 44 160 solid copper pipe strap a 48 standard top beam clamp a 375 92 406 406 wide mouth top beam clamp a 400 93/94 407 407 underground bell clamp a 122 600 35 175 ...

d-12 thrust restraint restrained joint pipe ... pipes up to 16-inch diameter d-14 brick masonry valve basin d-16 typical 1-inch to 2-inch water service d-18 casing pipe under railroad track detail d-19 (1 of 2) water mains crossing over sewers and house drains ... exist survey iron pipe exist property corner survey traverse point exist conc i.d ...

Pipe line laying route cleared, alignment marked and approved by OIC Trial pits test done and all the existing services are identified and protected along the pipe laying route All necessary shop drawings and connection details are submitted and approved Laying New Pipeline -Ductile Iron Pipe CHECKLIST 2201 Y N NA Y N NA Y N NA Y N NA Y N NA Y ...

threading on ductile iron pipe are ductile iron in accordance with AWWA C115. (AMERICAN recommends only ductile iron flanges for strength and safety, though AWWA C115 currently allows both ductile iron and gray iron flanges.) Flanges conform to the chemical and physical properties specified for ductile iron fittings in AWWA C110.

"Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings". olts shall be stainless steel Type 316. Flanged joints shall not be used in underground installations without prior approval. (Drawing PST 101) C. DUCTILE IRON FITTINGS Ductile iron standard and special fittings shall conform to ANSI/AWWA A21.53/153, "Ductile Iron

2.01 DUCTILE IRON PIPE Pipe shall be ductile iron conforming to AWWA C151. Provide pipe in nominal 18- or 20-foot laying lengths. 2.02 PIPE MARKING Plainly mark each length of straight pipe to identify the design pressure class or thickness class, the wall thickness, and date of manufacture. Mark the spigot end of restrained joint

for ductile cast iron pipes 4 13547-b-z wide flange manhole head & cover, cast iron 21 44387-z-b rodding all special castings, lead & mechanical joints on low pressure water mains, push-on joint pipe 5 18583-z large manhole frame & cover 22 44573-w standard chamber for …

installation detail dwg. norevisions date revisions date w-4 minimum 36" horizontal clearance from any object. notes: 1. fire hydrant shall be as manufactured: mueller, american darling, kennedy, m&h, waterous, clow, east jordan iron works, or us pipe. 2. branch pipe shall be ductile iron awwa c150-96 3. 6" gate valve shall be awwa c500-86 open ...

4) Thrust forces may also occur at the locations where new pipe is connected in-line to a different type of existing pipe with different sealing diameters. A significant example of this is the connection of large diameter Prestressed Concrete Cylinder Pipe (PCCP) and Ductile Iron Pipe (DIP).

Jan 16, 2013· Pipe Fittings – FT Ductile – Ductile Iron Pipes. Fittings to suit ductile iron pipes are available from 80mm to 1000mm and CAD drawings of our pipe fittings can be provided. »More detailed

The transition between the underground ductile iron pressure pipe and the building pipe shall be accomplished with a flange located inside the building. For new installations, specify that the termination of the ductile iron pipe (and any ... Indicate locations and details of …

half of a pipe length of the station indicated on the Drawings. The use of pipe containing asbestos materials shall be prohibited. B. Ductile Iron Pipe Ductile iron pipe shall conform to requirements of ASTM A-746 (AWWA C-151) and Cement Mortar shall conform to …

available for Ductile Iron Pipe than for any other piping material, providing greater flexibility and versatility in pipeline design and installation. Push On Joints The most popular, quickest, and easiest-to-assemble joint for Ductile Iron Pipe and fittings in underground applications is the push-on joint.

Reinforced Concrete Pipe, Class V with an approved lining/coating. For rigid pipes, the maximum depth of cover shall be not more than 13.5 feet. For depth of cover more than 13.5 feet refer to Standard Detail D-1. Class IV reinforced concrete pipe with approved lining/coating or ductile iron pipe Class 52 may be acceptable with design calculation.

A. This Section covers ductile iron pipe fittings, flanges, specials, and other accessories. 1.2. SUBMITTALS A. Certification. 1. Submit manufacturer's certification that products meet the referenced standards. B. Shop Drawings. 1. Submit manufacturer's specifications and details for all ductile iron pipe and accessories. 2.

DESIGN OF DUCTILE IRON PIPE ON SUPPORTS D ESIGN PROCEDURES FOR Ductile Iron pipe in nor-mal underground service have been well estab-lished. The standard design considers hoop stresses in the pipe wall due to internal hydrostatic pressure as well as bending stresses and deflection in the pipe due to external loads of earth and traffic above the ...

Ductile Iron Pipe shall conform to AWWA C150 and ANSI A21.50, shall be designed for pressure class as follows unless otherwise noted: a) 4-12" 350 b) 14-20" 250 c) 24"-26" 200 d) 30" & greater 150 3. Ductile iron pressure pipe shall conform to ASTM A377. Pipe shall have push-on or

Oct 01, 2021· W6.10A- Steel Pipe Buttstrap (PDF) W6.11- 4 Inch to 16 Inch In-Line Thrust Block for Ductile Iron Pipe (PDF) W6.12A- Wrought Iron Fence and Gate Detail (PDF) W6.12B- Wrought Iron Drive Swing Gate Detail (PDF) W6.12C- Wrought Iron Drive Swing Gate Operator Detail (PDF) W6.12D- Chain Link Fence Detail (PDF) W6.12E- Chain Link Gate Detail (PDF)

2.9 DUCTILE-IRON PIPE AND FITTINGS A. Ductile-Iron, Mechanical-Joint Piping: 1. Ductile-Iron Pipe: AWWA C151/A21.51, with mechanical-joint bell and plain spigot ends unless grooved or flanged ends are indicated. 2. Ductile-Iron Fittings: AWWA C110/A21.10, mechanical-joint, ductile- or gray-iron standard pattern or AWWA C153/A21.53, ductile-iron ...

ENGINEERING DRAWINGS DETAIL REFERENCE CHART Please note Engineering Drawings require the free ... Typical Above Ground Ductile Iron Pipe: FM-DxPV-AG-01: Request CAD Files ... Typical Above Ground Roller Support: FM-DxPV-AG-02: Request CAD Files: Ductile: Ductile Iron Fitting: FM-DxPV-E-01: Request CAD Files: Ductile: 45° Ductile Iron Elbow: FM ...

Newsleter

Back-To-Top
Choose Your Color